Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Front Cardiovasc Med ; 11: 1367463, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38455720

RESUMO

Purpose: To evaluate the feasibility and accuracy of quantification of calcified coronary stenoses using virtual non-calcium (VNCa) images in coronary CT angiography (CCTA) with photon-counting detector (PCD) CT compared with quantitative coronary angiography (QCA). Materials and methods: This retrospective, institutional-review board approved study included consecutive patients with calcified coronary artery plaques undergoing CCTA with PCD-CT and invasive coronary angiography between July and December 2022. Virtual monoenergetic images (VMI) and VNCa images were reconstructed. Diameter stenoses were quantified on VMI and VNCa images by two readers. 3D-QCA served as the standard of reference. Measurements were compared using Bland-Altman analyses, Wilcoxon tests, and intraclass correlation coefficients (ICC). Results: Thirty patients [mean age, 64 years ± 8 (standard deviation); 26 men] with 81 coronary stenoses from calcified plaques were included. Ten of the 81 stenoses (12%) had to be excluded because of erroneous plaque subtraction on VNCa images. Median diameter stenosis determined on 3D-QCA was 22% (interquartile range, 11%-35%; total range, 4%-88%). As compared with 3D-QCA, VMI overestimated diameter stenoses (mean differences -10%, p < .001, ICC: .87 and -7%, p < .001, ICC: .84 for reader 1 and 2, respectively), whereas VNCa images showed similar diameter stenoses (mean differences 0%, p = .68, ICC: .94 and 1%, p = .07, ICC: .93 for reader 1 and 2, respectively). Conclusion: First experience in mainly minimal to moderate stenoses suggests that virtual calcium removal in CCTA with PCD-CT, when feasible, has the potential to improve the quantification of calcified stenoses.

3.
Am J Cardiol ; 122(12): 2095-2103, 2018 12 15.
Artigo em Inglês | MEDLINE | ID: mdl-30293652

RESUMO

Preoperative evaluation of the mitral valve but also of tricuspid valve and right ventricular (RV) function is mandatory in primary mitral regurgitation (MR) secondary to mitral valve prolapse (MVP). Tricuspid annulus (TA) diameter plays a pivotal role in the surgical decision to perform preventive combined tricuspid valve annuloplasty. Cardiac magnetic resonance (CMR) is the gold standard for the assessment of RV size and function. Based on 70 consecutive patients (17 women; mean age 64 ± 12) with severe MR secondary to MVP referred for CMR, we sought to assess RV geometry and function and TA dimensions and to study the interaction between TA dilatation and right-sided cardiac chambers. Frequency of RV dilatation, RV systolic dysfunction, and TA dilatation (TA diameter ≥ 40 or 21 mm/m²) were 11%, 51%, and 49%, respectively. Left ventricular (LV) end-diastolic volume index was the only independent predictor of RV dilatation. Presence of symptoms, larger LV end-diastolic volume index, and LV ejection fraction <60% were independently associated with RV dysfunction. Absolute TA diameter was 36 ± 6 mm and TA diameter index was 20 ± 3 mm/m². Reproducibility TA diameter measurement was excellent (coefficient of variation ≤10%). TR velocity >220 cm/s (odds ratio = 20.17; [3.57 to 113.90]; p = 0.001 and right atrial volume index ≥ 38 ml/m² (odds ratio = 13.44; [3.57 to 50.54]; p = 0.0001) were independent predictors of TA diameter ≥40 or 21 mm/m². CMR provides accurate right-sided cardiac chambers assessment and may help surgical planning of concomitant tricuspid valve annuloplasty before mitral valve repair in severe MR secondary to MVP. In conclusion, TA dilatation, RV enlargement, and dysfunction are related to pulmonary pressure and left-sided cardiac chambers enlargement, reflecting the long-standing consequences of severe MR.


Assuntos
Ventrículos do Coração/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico , Prolapso da Valva Mitral/fisiopatologia , Valva Mitral/diagnóstico por imagem , Função Ventricular Direita/fisiologia , Remodelação Ventricular , Idoso , Feminino , Seguimentos , Ventrículos do Coração/diagnóstico por imagem , Humanos , Imagem Cinética por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/fisiopatologia , Prolapso da Valva Mitral/complicações , Prolapso da Valva Mitral/diagnóstico
4.
Arch Cardiovasc Dis ; 111(8-9): 507-517, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29610031

RESUMO

BACKGROUND: Quantitative assessment of primary mitral regurgitation (MR) using left ventricular (LV) volumes obtained with three-dimensional transthoracic echocardiography (3D TTE) recently showed encouraging results. Nevertheless, 3D TTE is not incorporated into everyday practice, as current LV chamber quantification software products are time consuming. AIMS: To investigate the accuracy and reproducibility of new automated fast 3D TTE software (HeartModelA.I.; Philips Healthcare, Andover, MA, USA) for the quantification of LV volumes and MR severity in patients with isolated degenerative primary MR; and to compare regurgitant volume (RV) obtained with 3D TTE with a cardiac magnetic resonance (CMR) reference. METHODS: Fifty-three patients (37 men; mean age 64±12 years) with at least mild primary isolated MR, and having comprehensive 3D TTE and CMR studies within 24h, were eligible for inclusion. MR RV was calculated using the proximal isovelocity surface area (PISA) method and the volumetric method (total LV stroke volume minus aortic stroke volume) with either CMR or 3D TTE. RESULTS: Inter- and intraobserver reproducibility of 3D TTE was excellent (coefficient of variation≤10%) for LV volumes. MR RV was similar using CMR and 3D TTE (57±23mL vs 56±28mL; P=0.22), but was significantly higher using the PISA method (69±30mL; P<0.05 compared with CMR and 3D TTE). The PISA method consistently overestimated MR RV compared with CMR (bias 12±21mL), while no significant bias was found between 3D TTE and CMR (bias 2±14mL). Concordance between echocardiography and CMR was higher using 3D TTE MR grading (intraclass correlation coefficient [ICC]=0.89) than with PISA MR grading (ICC=0.78). Complete agreement with CMR grading was more frequent with 3D TTE than with the PISA method (76% vs 63%). CONCLUSION: 3D TTE RV assessment using the new generation of automated software correlates well with CMR in patients with isolated degenerative primary MR.


Assuntos
Ecocardiografia Tridimensional/métodos , Ventrículos do Coração/diagnóstico por imagem , Hemodinâmica , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Insuficiência da Valva Mitral/diagnóstico por imagem , Valva Mitral/diagnóstico por imagem , Software , Função Ventricular Esquerda , Idoso , Automação , Estudos de Viabilidade , Feminino , França , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/fisiopatologia , Mônaco , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
5.
Arch Cardiovasc Dis ; 110(11): 580-589, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28566200

RESUMO

BACKGROUND: Three-dimensional (3D) transthoracic echocardiography (TTE) is superior to two-dimensional Simpson's method for assessment of left ventricular (LV) volumes and LV ejection fraction (LVEF). Nevertheless, 3D TTE is not incorporated into everyday practice, as current LV chamber quantification software products are time-consuming. AIMS: To evaluate the feasibility, accuracy and reproducibility of new fully automated fast 3D TTE software (HeartModelA.I.; Philips Healthcare, Andover, MA, USA) for quantification of LV volumes and LVEF in routine practice; to compare the 3D LV volumes and LVEF obtained with a cardiac magnetic resonance (CMR) reference; and to optimize automated default border settings with CMR as reference. METHODS: Sixty-three consecutive patients, who had comprehensive 3D TTE and CMR examinations within 24hours, were eligible for inclusion. Nine patients (14%) were excluded because of insufficient echogenicity in the 3D TTE. Thus, 54 patients (40 men; mean age 63±13 years) were prospectively included into the study. RESULTS: The inter- and intraobserver reproducibilities of 3D TTE were excellent (coefficient of variation<10%) for end-diastolic volume (EDV), end-systolic volume (ESV) and LVEF. Despite a slight underestimation of EDV using 3D TTE compared with CMR (bias=-22±34mL; P<0.0001), a significant correlation was found between the two measurements (r=0.93; P=0.0001). Enlarging default border detection settings leads to frequent volume overestimation in the general population, but improved agreement with CMR in patients with LVEF≤50%. Correlations between 3D TTE and CMR for ESV and LVEF were excellent (r=0.93 and r=0.91, respectively; P<0.0001). CONCLUSION: 3D TTE using new-generation fully automated software is a feasible, fast, reproducible and accurate imaging modality for LV volumetric quantification in routine practice. Optimization of border detection settings may increase agreement with CMR for EDV assessment in dilated ventricles.


Assuntos
Ecocardiografia Tridimensional/métodos , Interpretação de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Software , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda , Idoso , Automação , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Disfunção Ventricular Esquerda/fisiopatologia
6.
Arch Cardiovasc Dis ; 109(11): 618-625, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27692661

RESUMO

BACKGROUND: Recently, 1.5-Tesla cardiac magnetic resonance imaging (CMR) was reported to provide a reliable alternative to transthoracic echocardiography (TTE) for the quantification of aortic stenosis (AS) severity. Few data are available using higher magnetic field strength MRI systems in this context. AIMS: To evaluate the feasibility and reproducibility of the assessment of aortic valve area (AVA) using 3-Tesla CMR in routine clinical practice, and to assess concordance between TTE and CMR for the estimation of AS severity. METHODS: Ninety-one consecutive patients (60 men; mean age 74±10years) with known AS documented by TTE were included prospectively in the study. RESULTS: All patients underwent comprehensive TTE and CMR examination, including AVA estimation using the TTE continuity equation (0.81±0.18cm2), direct CMR planimetry (CMRp) (0.90±0.22cm2) and CMR using Hakki's formula (CMRhk), a simplified Gorlin formula (0.70±0.19cm2). Although significant agreement with TTE was found for CMRp (r=0.72) and CMRhk (r=0.66), CMRp slightly overestimated (bias=0.11±0.18cm2) and CMRhk slightly underestimated (bias=-0.11±0.17cm2) AVA compared with TTE. Inter- and intraobserver reproducibilities of CMR measurements were excellent (r=0.72 and r=0.74 for CMRp and r=0.88 and r=0.92 for peak aortic velocity, respectively). CONCLUSION: 3-Tesla CMR is a feasible, radiation-free, reproducible imaging modality for the estimation of severity of AS in routine practice, knowing that CMRp tends to overestimate AVA and CMRhk to underestimate AVA compared with TTE.


Assuntos
Estenose da Valva Aórtica/diagnóstico , Valva Aórtica/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Idoso , Ecocardiografia Doppler , Feminino , Seguimentos , Humanos , Masculino , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença
7.
Am Heart J ; 169(6): 841-6, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26027622

RESUMO

BACKGROUND: The purpose of the study was to determine the long-term prognostic value of normal adenosine stress cardiac magnetic resonance imaging (CMR) in patients referred for evaluation of myocardial ischemia. METHODS: We reviewed 300 consecutive patients (age 65 ± 11 years, 74% male) with suspected or known coronary disease and normal wall motion who had undergone adenosine stress CMR negative for ischemia and scar. Most patients were at intermediate risk of coronary artery disease. The end points studied were all causes of mortality and major adverse cardiac events, including cardiac death, myocardial infarction, revascularization, and hospitalization for unstable angina. RESULTS: During a mean follow-up of 5.5 years (mean = 5.4 ± 1.1), 16 patients died because of various causes (cardiac death in 5 patients). Three patients had a nonfatal myocardial infarction, 7 patients were hospitalized for revascularization, and 11 were medically treated for unstable angina. The annual cardiac event rate was 1.3% (0.78% in the first 3 years and 1.9% between the fourth and sixth years). The predictors of major adverse cardiac events in a multivariate analysis model were as follows: advanced age (hazard ratio [HR] 1.15, 95% confidence interval [95% CI] 1.02-1.30), diabetes (HR 17.5, 95% CI 2.2-140), and the habit of smoking (HR 5.9, 95% CI 1.0-35.5). For all causes of mortality, the only predictor was diabetes (HR 11.4, 95% CI 1.76-74.2). Patients with normal stress CMR had an excellent outcome during the 3 years after the study. The cardiac event rate was higher between the fourth and sixth years. CONCLUSION: Over a 5.5-year period, a low event rate and excellent prognosis occurred in patients with normal adenosine stress CMR. Low- to intermediate-risk patients with a normal CMR are at low risk for subsequent cardiac events.


Assuntos
Adenosina , Doença das Coronárias/diagnóstico , Angiografia por Ressonância Magnética/métodos , Isquemia Miocárdica/diagnóstico , Idoso , Causas de Morte , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Medição de Risco
8.
Am J Cardiol ; 107(4): 516-21, 2011 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-21184991

RESUMO

A paucity of data on outcome of coronary multislice computed tomography (CT) is available. The aim of this study was to assess the long-term follow-up of 64-slice CT in a homogenous patient group. In total 222 patients (136 men, 61%, 59 ± 11 years of age) with chest pain at intermediate risk of coronary artery disease (CAD) and no previous CAD underwent 64-slice CT. Coronary lesions were considered significant or not based on a threshold of 50% luminal narrowing. Plaques were classified as calcified, noncalcified, and mixed based on type. End point during follow-up was major adverse cardiac events (nonfatal myocardial infarction, unstable angina requiring hospitalization, myocardial revascularization). Coronary plaques were detected in 162 patients (73%). Coronary artery stenosis was significant in 62 patients. Normal arteries were found in 59 patients (27%). During a mean follow-up of 5 ± 0.5 years, 30 cardiac events occurred. Annualized event rates were 0% in patients with normal coronary arteries, 1.2% in patients with nonsignificant stenosis, and 4.2% in patients with significant stenosis (p <0.01). Predictors of cardiac events were presence of significant stenosis, proximal stenosis, and multivessel disease. Noncalcified and mixed plaques had the worse prognosis (p <0.05). In conclusion, 64-CT provides long-term incremental value in patients at intermediate risk of CAD.


Assuntos
Dor no Peito/diagnóstico por imagem , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Idoso , Angina Instável/diagnóstico por imagem , Angiografia Coronária/métodos , Doença da Artéria Coronariana/patologia , Estenose Coronária/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Revascularização Miocárdica , Valor Preditivo dos Testes , Prognóstico , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Sensibilidade e Especificidade , Inquéritos e Questionários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...